Role
Cast-iron motors where stiffness and vibration damping are needed in severe duty.
Parameters
- Efficiency class and duty (S1 baseline) with ambient/altitude derating.
- IP rating, insulation class, bearing types and regreasing intervals.
- IEC mountings (B3/B5/B14) and terminal box orientation.
Checks
- Confirm supply (voltage/frequency) and start method vs. protection devices.
- Assess load inertia and start frequency; verify shaft height/frame.
- Select seals for dust/humidity/chemicals; log baseline vibration.